Solution
WaStop® Inline Check valve
Karlshamn Municipality contacted Wapro for advise and was recommended to use several WaStop DN300 inline check valves between the ponds to achieve the staged filling and emptying.
At time of peak flow when the pump station is overloaded the overflow flows into the first basin, then overflows into the second basin and so on. WaStop inline check valves are utilized to prevent the wastewater from flowing into all the pools simultaneously. Having staged filling means that the minimal number of ponds are used which leads to reduced maintenance in the plant.
When inflow to the pump station is reduced the WaStop’s allow the wastewater to flow from the ponds back into the pump station to pump further on to Sternö Treatment plant.
Repurposing the treatment plant in Mörrum with the use of WaStop, has protected the environment and utilized resources without increasing maintenance and costs.